PRODUCT
CONTACT
  • ADDRESS:No.111 NanJing Road Shibi Industrial Area Panyu District of GuangZhou GuangDong,P.R.China
  • TEL:+86 20 83687691
  • FAX:+86 20 83687779
  • Email:nkautomatic@126.com
 
Optical power meter source optical cable contact>

  NKOPM-21A series of optical power meter            NKOPM-21A系列光功率计
 
 
 
   
 
 
 
 
Product overview
NKOPM-21A series handheld optical power meter is for the installation, operation and maintenance of optical fiber network specially designed a kind of accurate, durable, portable instrument. With flexible shape, can choose to switch backlight display and automatic shutdown function, super wide light power test range, precision testing accuracy and user self calibration function and general interface design, and the linear index (mW) and nonlinear index (dBm) with screen display.
The characteristics of the product
User self calibration function
9V battery used general, up to 240 hours of continuous work time
Linear and nonlinear indexes (mW) (dBm) at the same time display
FC/SC/ST universal interface is unique, no need of complicated conversion
Optional automatic shutdown function
Optional on / off backlight display
Technical indicators
 
 
The instrument model NKOPM-21A NKOPM-21AC
The wavelength range of 800 ~ 1700 (nm)
The probe type InGaAs
Power measurement range (dBm) +3 -70 ~ -50 ~ +26
Uncertainty of plus or minus 5%
Standard length (nm) of 850, 980, 1300, 1310, 1490, 1550
Display resolution: 0.1% linear display log display: 0.01dBm
Working temperature (c) -10 ~ +60
Storage temperature (c) -25 ~ +70
Automatic shutdown time (min) 10
Battery duration (H) 240
Outline dimension (mm) 172 x 82 x 33
Power 9V battery
Weight (g) 310
 
 
 
产品概述
 
 
 
NKOPM-21A系列手持式光功率计是为安装、运营和维护光纤网络专门设计的一种精准、耐用、的便携式仪表。具有灵活的外形、可选择开关的背光显示和自动关机功能、超宽的光功率测试范围、精准的测试精度以及用户自校准功能和通用接口设计,同时线性指标(mW)和非线性指标(dBm)同屏显示。
产品特性
用户自校准功能
采用通用的9V电池,长达240小时的连续工作时间
线性(mW)和非线性指标(dBm)同时显示
独到的FC/SC/ST通用接口,无需复杂转换
可选的自动关机功能
可选开/关的背光显示
 
技术指标

Instrument type 仪表型号
NKOPM-21A
NKOPM-21AC
The wavelength range波长范围(nm)
800~1700
The probe type 探头类型
InGaAs
Power measurement range 功率测量范围(dBm)
-70~+3
-50~+26
Uncertainty不确定度
±5%
The standard wavelength标准波长(nm)
850、980、1300、1310、1490、1550
Display resolution显示分辨率
线性显示:0.1% 对数显示:0.01dBm
Working temperature工作温度(℃)
-10~+60
Storage temperature存储温度(℃)
-25~+70
Automatic shutdown time自动关机时间(min)
10
Battery duration电池持续工作时间(h)
240
size外形尺寸(mm)
172×82×33
power supply电源
9V 电池
weight重量(g)
310

 
Note:
1 wavelength range: the provisions of the work wavelength lambda range from a standard min lambda to lambda max, optical power in the wavelength range of the design can work in the specified index.
2 power measurement range: according to the index range measurement of the maximum light power of the regulations.
3 uncertainty: the error between test results of a certain light power and standard optical power test results.
Function description
Panel diagram
 
 
注意
1. 波长范围:规定一个标准的工作波长λ范围从λmin至λmax,在此波长范围内设计的光功率计能在规定的指标下工作。
2. 功率测量范围:能按规定的指标测量最大光功率的范围。
3. 不确定度:对某一确定的光功率的测试结果与标准光功率测试结果之间的误差。
功能说明
面板简图
 
 
 
 

 1, LCD display
LCD optical power measured values, with dB, dBm, mW, uW, nW display form; set the wavelength of 850nm, 980 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm.
2, the ON/OFF key
Press the ON/OFF key to the liquid crystal display, you can start the SX-200N, at the same time in the boot state, press the button, you can shut down (to be in the boot after a second)
3, the dB key
In the setting of wavelength, relative measurement of optical power meter.
4, the ZERO key
Press the button, optical power meter from the zero.
5, lambda key
Lambda the wavelength selection key, press the key, can different wavelength selection, 850nm, 980 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm and six kinds of wavelength choice, the values will be displayed on the LCD.
6, the LIGHT key
Press the key to select to open and close the LCD backlight.
Operate Guidebook
The on / off
1 press and hold down the ON/OFF key, the surface of the plate on the LCD display, the completion of start-up.
2 press the ON/OFF button on the instrument panel, LCD displays, optical power meter off.
Absolute optical power measurement
1 open the light power meter.
The 2 set of wavelength measurement, selection of measuring wavelength by a key, the default setting is 1310nm.
The 3 access by photometry, the screen will display the current measurements, linear and nonlinear including absolute power value.
The relative optical power measurement
The 1 set of wavelength measurement.
2 in absolute optical power measurement mode, access to measure light, the measured value of the current power.
3 press the DB key, the current value of optical power become the reference value (in dBm)
The 4 access another measure light, show the absolute optical power current measuring light value and relative value of optical power.
Special function
NKOPM-21A has three kinds of working mode, the factory work mode and user mode, mode, usually in work mode.
The factory pattern
By the factory measurement, calibration
Modify user mode
At the same time, press the +Light key while the lambda, enter user mode. If lambda +Light key press. Then from the user mode, in work mode
The key combination set table

 

 

 The function button
Add 0.05 Light
The reduction of 0.05 dB
Save Zero
The wavelength lambda switching
Restore factory settings lambda + Zero
 
 
 
1、 LCD显示屏
   LCD显示所测得的光功率值,以dB,dBm,mW,uW,nW的形式显示;设定的波长850nm 、980 nm、1300 nm、1310 nm、1490 nm、1550 nm等。
2、 ON/OFF键
   按ON/OFF键至液晶有显示,即可启动SX-200N,同时在开机状态下,按下该键,即可关机(须在开机1秒钟后)
3、 dB键
   在设定波长下,进行光功率计的相对测量。
4、 ZERO键
   按动该键,进行光功率计的自调零。
5、 λ键
   λ波长选择键,按压该键,可以选择不同的波长,有850nm 、980 nm、1300 nm、1310 nm、1490 nm、1550 nm六种波长供选择,该值也将在LCD上显示。
6、 LIGHT键
   按动该键可以选择打开和关闭液晶的背光。
 
 
 
操作指南
开机/关机
1. 按住表面板上的ON/OFF键,LCD显示,开机完毕。
2. 按下仪表面板上的ON/OFF键,LCD无显示,光功率计关闭。
 
绝对光功率测量
1. 打开光功率计。
2. 设定测量波长,通过λ键选择测量波长,缺省设置为1310nm。
3. 接入被测光,屏幕显示为当前测量值,包括绝对功率的线性和非线性值。
 
相对光功率测量
1. 设定测量波长。
2. 在绝对光功率测量模式下,接入测量光,测得当前功率值。
3. 按动db键,当前光功率值成为当前参考值(以dBm为单位)
4. 接入另一测量光,显示当前测量光的绝对光功率值和相对光功率值。
 
特殊功能
NKOPM-21A有三种工作模式,工厂模式、用户模式、工作模式,平时总是进入工作模式。
工厂模式
由工厂进行测量、校正
用户修改模式
同时按下λ+Light键,则进入用户模式。如果再按下λ+Light键。则退出用户模式,进入工作模式
 
组合键设置表

功能
增加0.05
Light
减少0.05
dB
保存
Zero
切换波长
λ
恢复工厂设置
λ+ Zero

 Note: if the user's own calibration errors or operational errors, can be in "modify user" mode at the same time, according to the "a" and "Zero" key to make power meter back to factory condition.
10 minutes automatic shutdown function
Press LIGHT+dB to open / close the automatic shutdown function. When you open the shutdown function, the upper right of the screen showing off the mark, 10 minutes without a key press, automatic shutdown.
LED backlight on / off function
In, working mode, press LIGHT to open / close the backlight. When you open the backlight, mark the upper right of the screen will show a small sun, said backlight in the open state.
Standard configuration
 Instrument type configuration description
NKOPM-21A optical power meter NKOPM-21A optical power meter host
User's Manual
One 9V battery
Product warranty card
Clean cotton swab
Desiccant
Oxford soft
 
备注:如果用户自己校准出现偏差或者操作失误,可以在“用户修改”模式下同时按“λ”和“Zero”键使功率计恢复到出厂状态。
 
10分钟自动关机功能
按LIGHT+dB,打开/关闭自动关机功能。当打开关机功能时,屏幕右上显示关机标志,10分钟没有按键按下,则自动关机。
LED背光开/关功能
在, 工作模式下,按LIGHT,打开/关闭背光。当打开背光时,屏幕右上会显示一个小太阳的标志,表示背光在打开状态。
 
 
 
标准配置

仪表型号
配置描述
NKOPM-21A光功率计
NKOPM-21A光功率计主机
用户手册
9V电池一节
产品保修卡
清洁棉签
干燥剂
牛津软包

 Maintenance and maintenance
1 keep the sensor face clean, do no fat, no pollution, no use is not clean, non-standard adapter connector, do not insert end face polishing surface is poor, otherwise it will damage the sensor surface, so that the whole system performance greatly.
2 possible stick with an adapter.
3 once the optical power meter when not in use, immediately covered with dust cap, protect face clean, prevent the measurement error of long-term exposure dust adhesion in the air and produce.
4 be careful of pluggable optical adapter connector, avoid port cause scratch.
5 periodically clean the sensor surface. Clean the sensor surface, please use special cleaning cotton swab wipe gently along the circumferential direction.
6 if the long-term do not remove the battery, prevent battery damp the impact of its measurement.
Common fault
 Fault performance may cause the solution
LCD shows weak enough power to replace the battery
Boot no display power shortage / other re boot / battery replacement
LCD display data
Maintain constant or variable
Of weak optical adapter joint fault or dirt.
Turbidity / display locked detection optical adapter connector
Is correct; clean sensor
End
 
维护与保养
1. 经常保持传感器端面清洁,做到无脂、无污染,不使用不清洁、非标准适配器接头,不要插入抛光面差的端面,否则会损坏传感器端面,使整个系统的表现大打折扣。
2. 尽可能坚持用一种适配器。
3. 一旦光功率计不用时,立即盖上防尘帽,保护端面清洁,防止长期暴露在空气中附着的灰尘而产生的测量误差。
4. 小心插拔光适配器接头,避免端口造成刮痕。
5. 定期性地清洁传感器表面。清洁传感器表面时,请使用专用清洁棉签沿圆周方向轻轻擦拭。
6. 若长期不用请取出电池,防止电池受潮而影响它的测量。
常见故障

故障表现
可能原因
解决办法
LCD显示微弱
电源不足
更换电池
开机无显示
电源不足/其他
重新开机/更换电池
LCD显示数据
保持不变或变
化微弱
光适配器接头故障或污
浊/显示被锁定
检测光适配器接头连接
是否正确;清洁传感器
端面

 QA
We are not in favor of the user to repair NKOPM-21A.
The 1 instrument warranty period from the date of delivery within eighteen months. My company will be on the material and process the commitment of all its products, the warranty period from the date of delivery is valid for eighteen months. When products in the purchase were found to have quality problems, we will make the appropriate repair or replacement. But in any case, my company's liability shall not exceed the purchase price of the product.
2 if the instrument problems in the use of the process, according to the solutions to common troubleshooting tips are still unable to solve, the user shall not open the case, please contact our company marketing department or agents around the contact.
3 for the quality fault caused by manufacturing defects, our company is responsible for free repair or replacement of products.
This guarantee only applies to the normal use of the instrument, and no damage or improper use conditions.
NKOPM-21A warranty does not include the fault caused by the problem /:
1) without authorization the repair or modification of instrument
2) non proper use of use or accident, negligence
I have a picture of me with the products of company's warranty card (warranty registration card). Please fill the form together with a copy of the invoice to send back to my company, so that in the future we need maintenance, technical innovation, calibration of your instrument etc, there are source record.
Appendix
Optical loss measurements
The first step in setting reference (Reference) value
Open the NKOPM-21A optical power meter, by a key to select the correct working wavelength.
Open source (emission source), select the correct wavelength and make it stable (this process takes approximately 1-2 minutes).
The choice of a root is used for connecting the light source of optical fiber jumper, which we call the emission source jumper, clean emission jumper connector. Note: the emission source used by the optical fiber jumper must use by optical fiber. The optical fiber link is the same.
With the emission source jumper will light source (emission source) is connected with the NKOPM-21A optical power meter.
Optical power at this time of the value obtained by NKOPM-21A.
Note: the power of the value should be with the light source (emission source) itself set close to the value, if there is a big deviation, please pay attention to carefully clean the respective connecting end face or the timely replacement of emission source jumper.
The dB key press NKOPM-21A optical power meter, when the NKOPM-21A dB reading of 0, and at the same time the light power of the measured values are set to be the benchmark (Reference) value.
Note: NKOPM-21A is zero, the number of digits after the decimal point with minor changes, this is a normal phenomenon.
The second step optical link loss measurement
Keep the emission source jumper and light source (emission source) connection.
The light source (emission source) and NKOPM-21A respectively and the optical fiber links need to connect.
Note: clean connection end all, including fiber optic adapter required.
At this time NKOPM-21A readings is the loss to test the fiber link, the unit is dB (absolute optical power current value and display by dBm
质量保证
我们不赞成用户自行修理NKOPM-21A。
1. 仪表保修期自发货之日起十八个月内。我公司将对其所有产品的物料及工艺承诺,保修期为发货之日起十八个月内有效。当购买的产品在此期间被发现有质量问题,我公司将会做出相应的修理或更换。但在任何情况下,我公司的责任不会超过该产品的购买价。
2. 如果仪表在使用过程中出现问题,根据常见故障提示的解决方案仍无法解决,用户不得擅自打开机壳,请与我公司市场营销部或各地代理商联系。
3. 对于因生产缺陷造成的质量故障,我公司负责免费维修或更换产品。
此保证仅适用于正常使用仪表,而且无损坏或使用不当的条件下。
NKOPM-21A的保修并不包括由以下原因引起的问题/故障:
1) 对仪表进行无授权修理或修改
2) 非恰当使用、疏忽使用或意外等
 
随同我产品均有一张我公司的保修卡(warranty registration card)。请您填写后连同发票复印件一同寄回我公司,以便日后我们需要对您的仪表进行维护、技术革新、校准等情况时,有根源记录。
附录
光纤损耗测量
 
第一步 设定基准(参考)值
打开NKOPM-21A光功率计,通过λ键来选择正确的工作波长。
打开光源(发射源),选择正确的波长并使其稳定(本过程大约需要1-2分钟)。
选择一根用来连接光源的光纤跳线,我们称之为发射源跳线,清洁发射跳线的连接器。注意:发射源跳线所使用的光纤必须与被测光纤链路所使用的光纤相同。
用发射源跳线将光源(发射源)与NKOPM-21A光功率计相连。
用NKOPM-21A得到此时的光功率值。
注意:此时测得的功率值应该与光源(发射源)本身的设定值相近,如果有较大偏差,请注意仔细清洁各个连接端面或者及时更换发射源跳线。
按NKOPM-21A光功率计的dB键,此时NKOPM-21A的dB的读数为0.00,并同时将所测的光功率值设置成为基准(参考)值。
注意:NKOPM-21A归零后,小数点后的位数会有轻微变化,这是正常现象。
第二步 光纤链路损耗测量
保持发射源跳线与光源(发射源)的连接。
把光源(发射源)与NKOPM-21A分别和需要的光纤链路进行连接。
注意:清洁所有的连接端面,包括所需的光纤适配器。
此时NKOPM-21A显示的读数就是被测光纤链路的损耗,单位为dB(同时以dBm方式显示当前的绝对光功率值)。
 
  
 
 

NKLS series laser source   NKLS系列稳定激光光源
 
  
 
 Product overview
NKLS-13 Series Portable stable light source can provide stable output of 1 to 4 wavelength according to the request of users, it can not only provide 650nm visible red light, can also provide dual wavelength laser output of 1310nm and 1550nm to single mode optical fiber measurement, or at the same time provide four 850/1300/1310/1550nm wavelength laser output, is the ideal test instrument of optical fiber engineering.
The characteristics of the product
High stable multi wavelength single (multi) mode laser output, CW or modulation
Large LCD display working wavelength state
The continuous working time of up to 45 hours
One key switching of the operating wavelength, flexible and convenient operation
Automatic shutdown can be set
Technical indicators
 
The instrument model NKLS-13
The operating wavelength (nm) according to the need to set 1 to 4 wavelengths
The light emitting device FP-LD
The optical output power (dBm) 0 (650nm) /-7/-7
Modulation of CW/2Hz (650nm) /270Hz, 1KHz (1310nm, 1550nm)
Optical fiber category SM, MM
Connector FC/PC
Working temperature (c) -10 ~ +60
Storage temperature (c) -25 ~ +70
Automatic shutdown time (min) 10
Battery duration (H) 45
Outline dimension (mm) 172 x 82 x 33
Power 1 9V batteries
Weight (g) 295
 
产品概述
NKLS-13系列手持式稳定光源可根据用户要求提供1到4个波长的稳定输出,既可以提供650nm可见红光,也可以向单模光纤测量提供1310nm和1550nm的双波长激光输出,或者同时提供850/1300/1310/1550nm四个波长激光输出,是光纤工程的理想测试仪表。
 
产品特性
高稳定度多波长单(多)模激光输出,CW方式或调制方式
大LCD显示工作波长状态
连续工作时间长达45个小时
单键切换工作波长,操作灵活方便
自动关机可设置
 
技术指标

仪表型号
NKLS-13
工作波长(nm)
根据需要设定1至4个波长
发光器件
FP-LD
光输出功率(dBm)
0(650nm)/-7/-7
调制
CW/2Hz(650nm)/270Hz,1KHz(1310nm,1550nm等)
光纤类别
SM,MM
连接器
FC/PC
工作温度(℃)
-10~+60
存储温度(℃)
-25~+70
自动关机时间(min)
10
电池持续工作时间(h)
45
外形尺寸(mm)
172×82×33
电源
1节9V电池
重量(g)
295

   Function description
Panel diagram
 

 
 
功能说明
 

 

 
面板简图   
   
 
1, the light output end
Signal by FC type optical fiber connector and the device under test is connected with the receiving end
2, LCD display
LCD display output wavelength value
3, the ON/OFF key
Press the button to open or close the light source.
4, the WAVE key
Press the key, can choose the output wavelength of different values, the value will be displayed on the LCD
5, the MODE key
The modulation frequency switching source. Switch between CW, 270Hz, 1000Hz, 2000Hz
Instructions for use
The 1 optical fiber connector access optical output port
2 press the ON/OFF button to open the NKLS-13, work light
The modulation frequency of 3 by pressing the WAVE button to adjust the light source
The modulation frequency of 4 by pressing the MODE button to adjust the light source
5 NKLS-13 handheld stable light source for various job status will be in the liquid crystal display instrument
6 off: press the ON/OFF key, lights out, LCD does not show off
Standard configuration
Instrument type configuration description
NKLS-13 stable light source NKLS-13 stable light source host
User's Manual
9V alkaline battery section
Product warranty card
Clean cotton swab
Desiccant
Oxford soft
 
1、 光输出端
可用FC型光纤连接器与被测器件的信号接收端相连
2、 LCD显示屏
LCD显示输出的光波长值
3、 ON/OFF键
按下该键,打开或关闭光源
4、 WAVE键
按下该键,可以选择不同的输出波长值,该值将在LCD上显示
5、 MODE键
切换光源的调制频率。在CW、270Hz、1000Hz、2000Hz之间进行切换
 
 
使用说明
 
1. 将光纤连接器接入光输出端口
2. 按下ON/OFF键打开NKLS-13,工作指示灯亮
3. 通过按动WAVE键来调整光源的调制频率
4. 通过按动MODE键来调整光源的调制频率
5. NKLS-13手持式稳定光源的各种工作状态都将在仪表的液晶上显示出来
6. 关机:按ON/OFF键,指示灯灭,LCD不显示,关机
  
标准配置

仪表型号
配置描述
NKLS-13稳定光源
NKLS-13稳定光源主机
用户手册
9V碱性电池一节
产品保修卡
清洁棉签
干燥剂
牛津软包

 
Maintenance and maintenance
The matters needing attention
1 avoid direct output at NKLS-13, the laser will hurt Hello eyes
2 if the long time does not use, users can dust cap to protect the light output port, the output end of the contaminated to avoid exposure in the air
3 when the stable source for use after a period of time, the light output may have adhesion in the dirt on the inner sleeve port, causing the decrease of the optical output power, then the user can be stained with alcohol cotton swab to remove dirt, and then dry cotton swab to remove traces of, if still not clean, please contact directly with the company
4 if not used for a long time, please timely battery is taken out, so as to avoid moisture affect the service life of battery
5 other fault please contact directly with the company, do not open the instrument repair itself, so as not to cause more severe fault. For privately disassembly the instrument, I will not repair
Common fault
The serial number of the fault phenomenon solution
Found the output light unstable replace the battery 1 use process
2 adapter port is not clean, gently scrub the stain with alcohol
The 3 instrument just boot, some fluctuations warmed up after 15 minutes and then use the output optical power
QA
We are not in favor of the user to repair NKLS-13.
The 1 instrument warranty period from the date of delivery within eighteen months. My company will be on the material and process the commitment of all its products, the warranty period from the date of delivery is valid for eighteen months. When products in the purchase were found to have quality problems, we will make the appropriate repair or replacement. But in any case, my company's liability shall not exceed the purchase price of the product.
2 if the instrument problems in the use of the process, according to the solutions to common troubleshooting tips are still unable to solve, the user shall not open the case, please contact our company marketing department or agents around the contact.
3 for the quality fault caused by manufacturing defects, our company is responsible for free repair or replacement of products.
This guarantee only applies to the normal use of the instrument, and no damage or improper use conditions.
NKLS-13 warranty does not include the fault caused by the problem /:
1) without authorization the repair or modification of instrument
2) non proper use of use or accident, negligence
I have a picture of me with the products of company's warranty card (warranty registration card). Please fill the form together with a copy of the invoice to send back to my company, so that in the future we need maintenance, technical innovation, calibration of your instrument etc, there are source record.
 The serial number of the fault phenomenon solution
Found the output light unstable replace the battery 1 use process
2 adapter port is not clean, gently scrub the stain with alcohol
The 3 instrument just boot, some fluctuations warmed up after 15 minutes and then use the output optical power
 
维护与保养
注意事项
1. 避免在NKLS-13工作时直视输出口,激光会伤害您好的眼睛
2. 若长时间不使用,用户可用防尘帽保护光输出口端口,避免输出端暴露在空气中被污染
3. 当稳定光源使用一段时期后,光输出端口上可能有黏附在内部套筒上的污垢,造成输出光功率的下降,这时用户可用沾上酒精的棉签清除污垢后,再用干棉签去除痕迹,若仍无法清洁干净,请与公司直接联系
4. 如果长期不用,请及时将电池取出来,以免电池受潮影响使用寿命
5. 其他故障请与公司直接联系,千万不要拆开仪表自行修理,以免造成更严重的故障。对于私自拆装过的仪表,我公司将不予维修
 
 
常见故障

序号
故障现象
解决办法
1
使用过程中发现输出光不稳定
请更换电池
2
适配器端口不清洁、有污渍
用酒精轻轻的擦洗
3
仪表刚开机时,输出光功率有些波动
开机预热15分钟后再使用

 
质量保证
我们不赞成用户自行修理NKLS-13。
1. 仪表保修期自发货之日起十八个月内。我公司将对其所有产品的物料及工艺承诺,保修期为发货之日起十八个月内有效。当购买的产品在此期间被发现有质量问题,我公司将会做出相应的修理或更换。但在任何情况下,我公司的责任不会超过该产品的购买价。
2. 如果仪表在使用过程中出现问题,根据常见故障提示的解决方案仍无法解决,用户不得擅自打开机壳,请与我公司市场营销部或各地代理商联系。
3. 对于因生产缺陷造成的质量故障,我公司负责免费维修或更换产品。
此保证仅适用于正常使用仪表,而且无损坏或使用不当的条件下。
NKLS-13的保修并不包括由以下原因引起的问题/故障:
1) 对仪表进行无授权修理或修改
2) 非恰当使用、疏忽使用或意外等
 
随同我产品均有一张我公司的保修卡(warranty registration card)。请您填写后连同发票复印件一同寄回我公司,以便日后我们需要对您的仪表进行维护、技术革新、校准等情况时,有根源记录。

 

  NKPON-21 series of optical power testing instrument  NKPON-21系列光功率测试仪
 
 
 Product overview
NKPON-21 optical power testing instrument is a new test instrument specific to my company FTTx/PON passive optical network test launch, using TFT color LCD HD, synchronous measurement experiment of voice, data and video signals and display on the BPON/EPON/GPON architecture. Can also set the power threshold, for each wavelength provided by, warning or fails to pass the state indicator. PON network engineering, construction and maintenance of the ideal.
Product characteristic
The 1 filter measurement function, at the same time test in PON system of 1490nm, 1550nm, power 1310nm three wavelength value corresponding to the.
2 for burst mode 1310nm uplink wavelength test.
3 dual port through design, during the test can guarantee the full communication of OLT to ONT.
4, by warning or not by indication, visual display is optical state 3 indicating lamps.
5 easy to use, simply connect the optical fiber can be read results.
TFT color LCD 6 HD
7 through the USB for data transmission, convenient and quick.
8.200 records can be stored in the device or computer software, view, delete.
9 through the backstage software set threshold, data upload, wavelength calibration.
10 automatic shutdown function, and can make the time settings, threshold settings on the device.
The technical index
Type NKPON-21
Calibration of wavelength 1310 uplink downlink downlink test 1490 test 1550 test
Pass band (nm) of 1260 ~ 13601470 ~ 15051535 ~ 1570
The detection range (dBm) -40 ~ +10 ~ -40 ~ +20 -40 +10
Isolation of 1310nm (dB) - >40 >40
Isolation of 1490nm (dB) >40 - >30
Isolation of 1550nm (dB) >40 >40
The accuracy of measurement
The inherent uncertainty (dB) + 0.5
Polarization dependent loss (dB) < + 0.25
Linear (dB) + 0.1
The insertion loss (dB) <1.5
General index
Display LCD:128 * 64
Unit of dB dBm xW
Resolution 0.01dB
Input voltage DC 6.5V ~ 8.5V
Rechargeable battery 7.4V
The AC adapter 8.4V
Optical fiber type single mode optical fiber
The working temperature of -10 to 60 DEG C
The storage temperature of -25 to 70 DEG C
Outline dimension (mm) 210 x 115 x 55
Application of the product
FTTx/Pon opened: in the opening stage, the measurement of all PON signal, verify and ensure to meet network standards;
FTTx/PON maintenance: all kinds of transmission problems in daily maintenance such as: connector endface fiber contaminated, macro bending, fracture, the optical terminal machine fault; will have a loss of signal or the transmission performance degradation.
And you can go to any location throughout the network ONT for easy assessment of the power value in OLT.
Can simultaneously measure and display the power of uplink and downlink wavelength 1310 1490 and 1550 three wavelength values.
The standard configuration:
The host (including rechargeable lithium battery), a rubber protection sleeve, USB data transmission line, the driver software CD, AC adapter, product warranty card, clean cotton swab.
The above parameters and configuration of any change without notice
◆ 产品概述 
NKPON-21光功率测试仪是我公司专门针对FTTx/PON 无源光网络测试推出的新款测试仪表,采用了高清的TFT彩色液晶, 可在BPON/EPON/GPON架构上实验语音、数据和视频信号的同步测量和显示。还可设置功率阈值,对每个波长提供通过、警告或未通过状态指示。是PON网络工程、施工和维护的理想选择。
◆ 产品特点 
1.滤波测量功能,同时测试PON系统中的1490nm,1550nm,1310nm三种波长相应的功率值。
2.用于1310nm上行波长的突发模式测试。
3.双端口直通设计,测试期间可保证 OLT 到 ONT 的全程通讯。
4.通过、警告或未通过指示,3个指示灯直观显示被测光路状态。
5.易于使用,只需连接光纤即可读取结果。
6. 高清的TFT彩色液晶
7.通过USB进行数据传送,方便快捷。
8.200条记录可在设备或上机位软件中保存,查看,删除。
9.通过后台软件设置阈值,上传数据,校准波长。
10.自动关机功能,并可在设备上进行时间设置、阈值设置。

◆ 技术指标 
型    号
NKPON-21
校准波长
1310上行测试
1490下行测试
1550下行测试
通带(nm)
1260~1360
1470~1505
1535~1570
检测范围(dBm)
-40~+10
-40~+10
-40~+20
隔离度1310nm(dB)
-
>40
>40
隔离度1490nm(dB)
>40
-
>30
隔离度1550nm(dB)
>40
>40
-
测量精确度
固有不确定度(dB)
±0.5
偏振相关损耗(dB)
<±0.25
线性(dB)
±0.1
通过插入损耗(dB)
<1.5
通用指标
显示
LCD:128×64
单位
dB dBm xW
分辨率
0.01dB
输入电压
DC 6.5V~8.5V
充电电池
7.4V
AC适配器
8.4V
光纤类型
单模光纤
工作温度
-10~60℃
存储温度
-25~70℃
外形尺寸(mm)
210 x 115 x 55
◆ 产品应用 
FTTx/Pon开通:在开通阶段,对所有PON信号进行测量,验证并确保满足网络标准;
FTTx/PON维护:日常维护中各种传输问题,如:连接器端面受污,光纤宏弯、断裂,光端机故障等;都会产生信号损耗或传输性能下降。
可以在OLT到 ONT的全程网络的任何位置对其中的功率值进行轻松评估。
可同时测量并显示上行1310 波长、下行1490 和 1550 三个波长上的功率值。
◆ 标准配置: 
主机(包含可充电锂电池)、橡胶保护套、USB数据传输线、驱动软件光盘、AC适配器、产品保修卡、清洁棉签。
以上参数及配置若有变化,恕不另行通知 
 
 
 
 
 
 
NKOTK-100A cable splice tool kit  NKOTK-100A 光缆接续工具箱  
 
  Tool name uses the serial number NKOTK-100A
The 1 optical fiber stripping pliers stripping fiber surface coating layer
2 horizontal cable cutter lateral stripping cable
3 cutting tool of object
The 4 cut in aramid fiber jumper
5 snake forceps stripping cable
The 6 pliers cut the cable core
The 7 combination screwdriver fastening screws
8 transverse beam tube knife cut fiber beam tube
9 adjustable wrench stripping cable
10 inner six angle wrench fastening screws
11 Ear Wash ball blowing lens surface of the floating layer
The 12 tweezers tweezers take small objects
The 13 marker pen to do terminal labeling
14 alcohol pump bottle washing fiber
15 mini screwdriver fastening screws
16 recording pen to record data
The 17 tape to measure the length of the cable stripping
The 18 device tools toolbox

序号
NKOTK-100A工具名称
用途
1
光纤剥皮钳
剥离光纤表面涂覆层
2
横向开缆刀
横向开剥光缆
3
刀具
切割物体
4
剪刀
剪断跳线内纺纶纤维
5
蛇头钳
开剥光缆
6
老虎钳
剪断光缆加强芯
7
组合螺丝批
紧固螺钉
8
横向束管刀
割断光纤束管
9
活动扳手
开剥光缆
10
内六角扳手
紧固螺钉
11
洗耳球
吹镜头表面浮层
12
镊子
镊取细小物件
13
记号笔
做终端标号
14
酒精泵瓶
清洗光纤
15
微型螺丝刀
紧固螺钉
16
记录笔
记录数据
17
卷尺
测量光缆开剥长度
18
工具箱
装置工具