PRODUCT
CONTACT
  • ADDRESS:No.111 NanJing Road Shibi Industrial Area Panyu District of GuangZhou GuangDong,P.R.China
  • TEL:+86 20 83687691
  • FAX:+86 20 83687779
  • Email:nkautomatic@126.com
 
Online infrared thermalgraphy temperature measure

 Online continuous infrared thermalgraphy & temperature measurement system

TCP/IP network RJ45 network cable power supply type distributed infrared thermalgraphy & temperature measurement system (network port RJ45 version) NKTEVA6

Real-time, continuity, easier to use RJ45 network power supply interface

very suitable for large network systems

Wide field of view, very suitable for monitoring

in electric high voltage and low voltage panels

Provide advanced thermal imaging solutions for on-site status monitoring:

Using a new VOx detector to distinguish more details; 25Hz frame rate network interface; more advanced MatrixⅢ image algorithm;

Reduced size and power consumption, easy to install; compatible with various industrial protocols, easy to realize automatic alarm, compatible with power monitoring SCADA interconnection

 

Product number NKTEVA6
detector  Uncooled infrared focal plane detector 240×180
thermal sensitivity <60mk
frame rate 25fps
Field of view 33.4°×25.4°
palette  At least 6 color palettes (black hot/white hot/iron red/etc)
Visible light parameters
resolution 1920×1080
fill light Built-in LED lights 
multispectral fusion
visible light fusion Dual-band image fusion enhancement 
temperature measurement
Temperature range -20°C ~ + 120°C (Support wide dynamic range -20°C to +400°C)
Temperature measurement accuracy ±2°C or 2% of range (2% of range under wide dynamic state)
Spot temperature measurement 6 movable points for temperature measurement, which can be
compared with the maximum temperature, minimum temperature, and average temperature of other temperature measurement points or temperature measurement areas
Area temperature measurement 6 movable areas for temperature measurement, with maximum temperature, minimum temperature and average temperature in the area, which can be compared with the maximum temperature, minimum temperature, and average temperature of other temperature measurement points or temperature measurement areas
line temperature measurement 1 line temperature measurement, the line has the highest temperature, the lowest temperature and the average temperature
Reference humidity manual setting
Atmospheric Transfer Correction Automatic, based on input values ​​for distance, atmospheric temperature and relative humidity
emissivity correction 0.01 to 1.0 
Reflected Apparent Temperature Correction Automatic, based on reflected temperature input
temperature correction Overall and individual target parameters
Call the police
Alarm function All temperature measurement points, all temperature measurement areas and the maximum temperature, minimum temperature and average temperature in the temperature measurement line can be configured with separate alarm output
Alarm Output I/O output, log, save image, file sending (FTP),
e-mail (SMTP), notification
protocol
ONVIF support
GB/28181 support
image stream
image stream format MJPEG/H.264
image storage
storage medium Built-in memory (Flash), optional built-in TF card, maximum support 64GB
file format JPEG, MP4
set up
B/S configuration interface B/S have
C/S configuration tool C/S have
SDK External output of original temperature data, users can carry out secondary development 
power supply
External power supply DC12V  
POE 802.3 at
external interface
M12 X type M12 X Contains 10M / 100M adaptive Ethernet port and POE power supply
M12 A type M12 A Contains DC12, alarm IO and analog video
Environmental parameters
degree of protection IP67
Operating temperature -20℃ to +60℃
storage temperature -40℃ to +70℃
humidity ≤95% 
electromagnetic compatibility EN 61000-6-2:2001 (Immunity)
EN 61000-6-3:2001 (Immunity)
FCC 47 CFR Part 15 Class B (Immunity)
impact resistance 25G, IEC68-2-29
Vibration resistance 2G, IEC68-2-6
physical parameters
size 55.5×30.3×87.5 mm (without connector)
55.5×30.3×101.4 mm (with connector)
Accessories (non-standard) Interface cable, bracket, cooling plate

 

The above data are for reference only, and the specific parameters of the listed products shall prevail.

Recommended configuration

Red array monitoring graphic display management software set         

red array controllers                          1          network RJ45 interface power supply and network  communication

array red array monitor  NKTEVA6          2       2000*1000*600  panels are recommended to install 2 or more in each electric panel,

(With a self-powered network TCP/IP module RJ45 interface, the length of the network cable to the instrument should not exceed 100 meters)