Integrated test system of generator characteristic

 

Integrated test system of generator characteristics of ARFD-2
Generator in the regular maintenance, the needs of a variety of characteristic curve of the generator and exciter were measured for comparison, to determine the maintenance results. The test method at present is: access many current meter, voltage meter, phase meter, test personnel each see a table, then a person starting, then each record their own meter readings, so there are the following risks:
(1) the test time is long, large energy consumption.
(2) generator test data, low accuracy, not timely, accurately determine the inspection results of the generator, may produce some hidden fault, fault caused by grid connected power when the generator.
(3) generator maintenance access needs a lot of testing instrument, cause many difficulties to the actual operation, and even easy to cause accident.
(4) excessive generator maintenance field personnel, prone to accidents etc..
In order to safe, accurate, effective comprehensive testing generator electrical parameters, our company in the reference of foreign advanced technology, combined with the actual situation in our country, the development of a comprehensive test system of the generator characteristics of RFD series "". The system which the notebook computer operating platform, data collector with specialization, making the generator electrical maintenance comprehensive testing more accurate, more timely, more convenient. Maintenance personnel in general simply training, can be freely to the operation of the whole test system.
Test 16 signals
1 ~ 150V AC voltage signal 3 Road
0 ~ 6A AC current signal Road 6
1 road 0 ~ 1000V DC voltage signal
0 ~ 75mV DC voltage signal 2 Road
0 ~ 750V AC voltage signal 3 Road
1 road 1200V speed signal
Attached: the system can also be tailored to customers a variety of signal module, the need for.
Function characteristics:
- once the test is successful, and to ensure the completeness of the data, thus saving a lot of fuel, and greatly reduce the repair cost.
- WINDOWS full Chinese interface, user-friendly design, operation is extremely easy.
- 16 test channels parallel generator electric start-up test.
- detection data is stable, accurate and reliable, can judge the maintenance of generator timely and correctly, to ensure the normal operation of the generator.
- using standard interface to adapt to all types of power plants (hydraulic power plant, thermal power plant and nuclear power plant) needs.
A variety of characteristic curve of real-time rendering -.
- chart data and also save.
- using the chart output, and archiving easier to analyze and judge.
- the system program of high degree, control points, strong anti-interference ability, high reliability.
- real time and standard (History) curve comparison, quickly determine whether qualified generator overhaul.
The test included:
- the generator no-load test
- generator short-circuit test
- frequency characteristic test
- de excitation time constant test
- excitation regulation dynamic test such as stepping up from zero, + 10% step
- main exciter no-load test
The test load - the main exciter
- channel switching test
......
The standard configuration of the number of standard configuration of the number of technical indicators
1 notebook computers dedicated software CD 1 sets of test signal: 16
Data collector for 1 special screwdriver 1 test accuracy: 0.2
The signal line 2 manual 2 the test temperature: 0 to +60 DEG C
Power cord 1 root certificate 1 working voltage: AC220V ~ + 10%
- the system with the help of cable fault detector front-end signal processor configuration, for cable fault detection using.
- the system can also carry out multimedia standard, for the usual office use.

 

 

发电机特性综合测试系统ARFD-2

发电机在定期检修以后,需要对发电机和励磁机的多种特性曲线进行测量比较,以判断检修结果。目前的测试手段是:接入众多的电流表、电压表、相位表,测试人员每人看一个表,再由一人发令,则每人记录自己仪表的读数,这样就存在以下隐患:  
(1)测试时间长,能耗大。  
(2)发电机检测数据少,准确性低,不能及时、准确地判断发电机的检修结果,有可能产生某些故障隐患,造成发电机并网发电时发生故障。  
(3)发电机检修需要接入大量的测试仪表,给实际操作造成很多困难,甚至容易造成事故。 
(4)发电机检修现场人员过多,容易发生意外事故等。
 
     为了能安全、准确、有效地对发电机电气参数进行综合测试,我公司在参考国外先进技术的同时,结合我国的实际情况,开发了RFD系列"发电机特性综合测试系统"。本系统以笔记本电脑为操作平台,配以专业化的数据采集器,使得发电机电气检修综合测试变得更准确,更及时、更方便。一般的检修人员只需简单培训,就可自如地操作整个测试系统。
测试信号 16路
1~150V交流电压信号       3路 
0~6A交流电流信号         6路
0~1000V直流电压信号      1路 
0~75mV直流电压信号       2路 
0~750V交流电压信号       3路 
1200V转速信号            1路 
附:本系统还可为客户量身订做各种信号模块,以供需要。
 
功能特点:
■ 一次测试成功,并确保数据的完备性,从而节约大量的燃油,大大降低了维修成本。
■ WINDOWS全中文界面,人性化设计,操作极为简便。
■ 16路测试通道可并行进行发电机电气总启动试验。
■ 检测数据稳定,精确可靠,能及时正确判断发电机的检修情况,以确保发电机正常运行。
■ 采用标准接口,以适应各类电厂(水力发电厂、火力发电厂及核能发电厂)的需要。
■ 实时绘制多种特性曲线。
■ 数据和图表同时保存。
■ 采用图表输出方式,更易于分析判断和存档。
■ 本系统程控化程度高,测控点多,抗干扰能力强,可靠性高。
■ 实时与标准(历史)曲线对比,迅速确定发电机是否检修合格。
试验项目包括:
■ 发电机空载试验
■ 发电机短路试验
■ 频率特性试验
■ 灭磁时间常数试验
■ 励磁调节动态试验如零起升压、±10%阶跃
■ 主励磁机空载试验
■ 主励磁机负载试验
■ 通道切换试验
……
标准配置          数量       标准配置       数量       技术指标
笔记本电脑        1台        专用软件光盘    1套       测试信号:16路
数据采集器        1台        专用螺丝刀     1把        测试精度:0.2级
信号线           2根        使用说明书      2本       测试温度:0℃~+60℃
电源线           1根        合格证         1份       工作电压:AC220V~±10% 
■ 本系统还可以与“电缆故障检测仪前置信号处理器”配置,以供电缆故障检测时使用。
■ 本系统还可以进行多媒体标准配置,以供平时办公使用。