PRODUCT
CONTACT
  • ADDRESS:No.111 NanJing Road Shibi Industrial Area Panyu District of GuangZhou GuangDong,P.R.China
  • TEL:+86 20 83687691
  • FAX:+86 20 83687779
  • Email:nkautomatic@126.com
 
Lightning protector power supply surge protection>

 

ABY-FS
Power lightning protection module series (40/20ka)

ABY-FS
电源防雷模块系列(40/20ka)

 

 

The main features:
Imported high quality varistors, high reliable quality assurance.
Modular design, convenient replacement.
Using the temperature control and circuit breakingtechnology, prevent fire.
With remote alarm contact (at the same time have a normally open and normally closed contacts) convenient remote monitoring (FBS).
Fast response time.
Through flow capacity, the maximum can reach 40kA.
Easy installation, simple maintenance.

主要特点:

   选用进口优质压敏电阻器,高可靠质量保证。

   模块式设计、更换方便。

   采用温控断路技术,避免火灾发生。

   带远程告警接点(同时拥有常开、常闭触点)方便远程监视(FBS) 。

   响应时间快。

   通流容量大,最大可达40kA。

   安装方便,维护简单。 

 ABY-F (S) three-phase lightning protection module is used for second level three phase AC power supply (C)lightning overvoltage protection.   ABY-F(S)三相防雷模块用于三相交流电源

 

 Technical parameters:  技术参数:

Model 型号
ABY-F(S)/4
ABY-F(2)/3
ABY-F(S)/3+1
The scope of application
适用范围
三相TN-S系统
三相TN-C系统
三相TT系统
Rated voltage标称电压
220/380Vac
Continuous working voltage持续工作电压
385Vac;320Vac
The nominal current capacity   标称通流容量(8/20uS)
20kA
The maximum flow capacity
40kA
Remote communication terminal type
遥信端子类型
常开、常闭、端子耐压/耐流AC;250V/1A
The level of protection
保护水平
1500V;1200V
Response time 响应时间
<25nS
Access the wire cross-sectional area
接入导线截面积
电源线≥6平方毫米,地线≥10平方毫米
install 安装方式
固定于35mm宽的导轨上
work environment工作环境
-40℃~+80℃;相对湿度:95%(25℃)
earth resistance接地电阻
≤4Ω


Installation method:
1, wiring diagram as shown in Fig.
2, the power supply connection wires for not less than 6 mm multi strand copper wire, grounding wire with not less than 10 mm multi strand copper wire, connecting line should be short, straight, thick.
3, lightning protection device front end series suitable fuse or breaker.


Installation notes:
1, the installation must be disconnected from the power supply, strictly charged operation, connecting wires must meet the requirements.
2, lightning protection device does not need special maintenance, only need to regularly check the connection status indicating whether there is loose, whether it is normal.
3, when the lightning protection module fault display window indicates red remote signal terminal output alarm signal (FBS) said the lightning protection device failure, should be promptly replaced.
4, after installation, the lightning protection module is inserted in the end, check whether the normal work. 931

 

安装方法:

  1、接线图如图所示

  2、电源连接导线用不小于6平方毫米的多股铜线,接地线用不小于10平方毫米的多股铜线,连接线应尽量的短、直、粗。

  3、防雷器前端应串联合适的熔断器或空开

 

安装注意事项:

  1、安装时必须断开电源,严禁带电操作,连接导线必须符合要求。

  2、防雷器无须特别维护,只需定期检查其连接是否有松动,状态指示是否正常。

  3、当防雷器模块故障显示窗口指示红色时遥信端子输出告警信号(FBS)则表示防雷器发生故障,应及时更换。

  4、安装完毕后,将防雷模块插到底,检查工作是否正常。931

的第二级(C级)雷电过电压防护。